Fume Cupboard Used in Secondary Schools – A Comprehensive Guide
Last updated on June 3, 2024
Fume Cupboard Used in Secondary Schools: A Comprehensive Guide
Fume cupboards used in secondary schools also known as fume hoods are the unsung heroes in science education in the UK. They allow students to experience practical chemistry and biology safely, fostering a love of discovery while minimising exposure to potentially harmful substances.
In the UK, specific regulations and best practices ensure that these essential pieces of equipment are being used effectively and we will cover these in greater detail later in this article.
So, you can get a feel for our authority on the subject of fume cupboard used in secondary schools, let me quickly outline our company history and achievements.
My name is Sarah, and I am partner at Holliday Technical Services, a fume cupboard specialist testing and maintenance company based in Yorkshire, UK. Holliday Technical Services https://www.fumecupboardservicing.co.uk has been providing fume cupboard testing, maintenance and fume cupboard repairs to schools and universities in the UK for over 18 years. Our sister company Holliday Fielding Hocking Ltd, supply and install new and used/refurbished fume cupboards to schools, colleges and universities and have been providing these services for over 5 generations.
We are the principal service contractor at several top universities in the UK where we routinely look after thousands of pieces of local exhaust ventilated equipment, arranging annual testing and repair and supplying new capital equipment including both ducted fume cupboards and ductless filtered fume cupboards, alongside supplying and maintaining Educational Fume Cupboards, Biosafety Cabinets, Laminar Flow, PCR Cabinets, Vented Chemical Storage solutions, Downflow Workstations, Extraction Arms and much more.
We also contract to hundreds of schools, offering ad-hoc and scheduled service and repair alongside annual fume cupboard testing using our own in-house trained engineers who all hold enhanced DBS. We fully comply with all UK standards relating to fume cupboard testing and can offer support on design, installation, commissioning and procurement of new and used/refurbished equipment.
Enough about us for the moment, we hope that when you need a specialist at your side that you choose to consider our services.
Let's delve into the world of fume cupboard used in secondary schools, covering everything from basic principles to technical specifications.
Section 1: Fume Cupboards Explained
How Fume Cupboards Work
Think of a fume cupboard as a specialised vacuum cleaner for harmful fumes and vapours. It's designed with a simple yet crucial principle: directing airflow away from the user and safely out of the lab. The main components are:
- Enclosure: The box-like structure that contains the experiment.
- Sash: The movable window that allows access while maintaining airflow.
- Exhaust System: Either a fan and ductwork (ducted type) or filters (ductless type) to remove contaminants.
Air is drawn into the cupboard through the open sash, across the work surface, and then out through the exhaust system. This continuous flow prevents hazardous fumes from escaping into the lab environment.
Types of Fume Cupboard Used in Secondary Schools
- Ducted Fume Cupboards: The most common type, these are connected to ductwork that vents fumes directly outside the building. They offer excellent protection and are suitable for a wide range of chemicals but require proper installation and maintenance.
- Ductless Filtered Fume Cupboards: These recirculate air through filters that trap harmful substances. They're more flexible in placement since they don't need external ducting, but they're limited to certain chemicals and may require more frequent filter changes.
- Demonstration Fume Cupboards: Designed with an open front, these are primarily used for teaching purposes. While they offer some protection, they should only be used with less hazardous substances and always under careful supervision.
Section 2: Using Fume Cupboards Safely and Effectively
Step-by-Step Guide
- Before Use:
- Visually check that the fume cupboard is in good condition (no damage or spills).
- Ensure the airflow indicator is functioning correctly.
- Position the sash at the correct height (marked on the cupboard).
- Arrange equipment to avoid blocking airflow and keep items at least 6 inches from the back and sides.
- During Use:
- Keep the sash at the designated height and minimise opening and closing. For schools, a recommended maximum working height of 400 mm allows for manipulation of apparatus in the fume cupboard but improves containment and provides some protection to the face of the user. A higher aperture increases user exposure to splashes and can reduce containment effectiveness.
- Work at least 6 inches inside the cupboard to maximise containment.
- Avoid rapid movements or actions that create turbulence.
- After Use:
- Leave the fume cupboard running for 5-10 minutes to purge any remaining fumes.
- Clean up spills immediately and wipe down all surfaces.
Common Mistakes to Avoid
- Overloading: Don't cram too much equipment inside, as this restricts airflow.
- Blocking Airflow: Make sure nothing obstructs the vents or baffles.
- Using for Storage: Store chemicals and equipment elsewhere to maintain proper airflow.
- Ignoring Alarms: Address any alarms or malfunctions promptly.
Student Safety
- Supervision: Always ensure students are supervised when using fume cupboards in schools.
- Clear Instructions: Provide clear, written instructions on safe fume cupboard use.
- Emergency Procedures: Make sure students know what to do in case of spills, alarms, or other incidents.
Section 3: Maintenance and Care
Regular maintenance is key to ensuring the safe and efficient operation of fume cupboard use in secondary schools.
Regular Checks
- Visual Inspections: Check for any visible damage, spills, or obstructions.
- Airflow Monitoring: Monitor the airflow indicator regularly. If it's not functioning correctly, contact a technician.
- Filter Replacement: If you have a ductless fume cupboard, follow the manufacturer's recommendations for filter replacement.
Professional Servicing
Fume cupboards should be professionally serviced annually. This typically includes a thorough inspection, cleaning, and calibration of the airflow system. It's essential to use qualified technicians who are familiar with the specific model of fume cupboard you have. HTS are specialists in providing a range of support services for fume cupboard used in secondary schools, and comply fully with British Standards, COSHH and HSG258 (Where relevant).
Section 4: Siting Considerations
The location of a fume cupboard used in secondary schools can significantly impact its effectiveness and safety. Here are some key factors to consider:
- Placement:
- Place fume cupboards away from doors, windows, and areas with high foot traffic.
- Consider the layout of the room and the types of experiments that will be performed.
- Utilities:
- Ensure adequate access to electrical outlets, gas lines (if needed), and water lines (if plumbed).
- Ventilation:
- Make sure the room has sufficient ventilation to provide makeup air for the fume cupboard.
- Avoid placing fume cupboards near sources of drafts, as this can disrupt airflow.
- Emergency Access:
- The fume cupboard should not obstruct emergency exits or pathways.
Section 5: Fume Cupboard Specifications
In the UK, fume cupboards must meet specific standards to ensure their safety and effectiveness.
Key Standards
- BS EN 14175: This is the main European standard for fume cupboard performance. It covers aspects like containment, face velocity, and robustness.
- BS 7989:2001: This standard applies to mobile fume cupboards and addresses their specific design and safety requirements.
Regulations
- COSHH (Control of Substances Hazardous to Health): COSHH is a UK regulation that requires employers to control exposure to hazardous substances in the workplace. Fume cupboards play a crucial role in achieving COSHH compliance by containing and removing harmful fumes and vapours. Schools must assess the risks associated with the chemicals used in experiments and ensure that fume cupboards are used appropriately to minimise exposure. You can find more information about COSHH on the Health and Safety Executive (HSE) website: https://www.hse.gov.uk/coshh/
Guidance and Support
- CLEAPSS: The Consortium of Local Education Authorities for the Provision of Science Services (CLEAPSS) provides invaluable guidance and resources for science safety in schools, including information on fume cupboard use and maintenance. Their website is a valuable resource: https://science.cleapss.org.uk/ and their resource pdf: G9 Fume Cupboards in Schools Revision of DfEE Building Bulletin 88: https://science.cleapss.org.uk/resource/g9-fume-cupboards-in-schools.pdf
Technical Terms Simplified
- Airflow Rate: The amount of air that passes through the fume cupboard per minute (usually measured in cubic meters per hour).
- Sash Height: The opening height of the sash, which affects containment and airflow.
- Face Velocity: The average speed of air entering the fume cupboard through the sash opening (usually measured in meters per second). Most schools fume cupboards work from a recommended face velocity of 0.4m/s. High face velocities can be problematic in schools (e.g. Bunsen burner flame outs) and lower face velocity can reduce containment.
The optimal values for these parameters depend on the type of fume cupboard and the substances being used.
Section 6: Services and Additional Features
Illumination
Fume cupboards used in secondary schools should have adequate lighting for safe work. Consider LED lights, which are energy-efficient and long-lasting.
Electrical Services
Outlets should be located outside the fume cupboard to avoid potential spark hazards. Ensure they are protected by Ground Fault Circuit Interrupters (GFCIs).
Gas Services
If your fume cupboard requires gas, it should be installed and maintained by a qualified professional. Gas lines should be clearly labelled and easily accessible for shut-off in case of emergency.
Water Services
If your fume cupboard is plumbed for water, regular checks for leaks and proper maintenance are essential.
Noise Levels
Fume cupboards can generate noise, which can be disruptive in a learning environment. Consider quieter models and ensure they are properly maintained to minimise noise levels.
Assumed Use
Fume cupboards used in secondary schools are typically used for general chemistry and biology experiments involving relatively low-risk substances. They are not designed for highly hazardous materials or large-scale reactions.
Conclusion
Fume cupboards used in secondary schools are invaluable tools in science education, providing a safe environment for students to explore the wonders of chemistry and biology. By understanding how they work, using them correctly, and maintaining them properly, you can ensure that your fume cupboards continue to serve your school safely and effectively for years to come.
Remember, safety is paramount. Always refer to your school's safety procedures and consult with qualified professionals if you have any questions or concerns.
Holliday Technical Services offer fume cupboard maintenance and testing in the UK. Visit our website for information on testing and maintenance for fume cupboard used in secondary schools and to view a wide selection of testimonials from schools such as yours.
When schools contact us to book fume cupboard servicing we will where possible try to accommodate schools fume cupboard testing in quieter times, such as before or after the learning day or during half term breaks. Our technicians are all time-served experts in fume cupboard servicing, who are used to working safely in educational settings. All engineers hold an Enhanced DBS certificate, they are asbestos trained, and work is carried out in accordance with the relevant British standards.
Visit: Holliday Technical Services to book your school fume cupboard service today. Holliday Technical Services are members of Reset Compliance Systems Ltd, Alcumus SafeContractor Ltd, Constructionline and BSI Group as well as being registered with the Environment Agency as a certified Upper Tier Waste Carrier and Dealer.
Fume Cupboards Used In Secondary Schools FAQs