Fume Cupboard Alarms & Airflow Monitoring

The most frequently replaced item on a fume cupboard. Full alarm kits, sensors and sash actuators, fitted by our own engineers and calibrated on site.

The only part of the cupboard that tells the user something is wrong

A fume cupboard gives almost no warning when its performance drops. Airflow can fall well below the design face velocity while the cupboard looks, sounds and behaves exactly as it always has. The person working at it has no way of knowing.

The monitor is what closes that gap. It measures continuously and alarms when flow drops out of specification, which is why it is the single most important component after the extract itself, and why a monitor that has drifted out of calibration is worse than none at all — it reports safety that is not there.

Monitors are also the item we replace most often. They are electronic, they are switched on permanently, and they age faster than the cupboard around them.

What we supply

Full kits, individual components, and the engineer to fit them

Available in different configurations. We will specify against the cupboard you have rather than sell one model for everything.

Complete alarm kits

Monitor, sensor, display and audible alarm as a matched set. The straightforward option where an old unit has failed outright or a cupboard never had one.

Sensors & transducers

Replacement sensing elements where the display and wiring are sound. Often the cheapest route back to a working alarm.

Sash actuators & position alarms

Automatic sash actuators, position switches and height alarms, fitted and set to the cupboard’s designated working aperture.

Control panels & interlocks

Panels, switchgear and interlocks that tie the monitor to the extract, so a fault does more than illuminate a light.

Included as standard

Engineering installation

Sensor positioning is the whole job. Put it in the wrong place in the duct or the aperture and the reading is meaningless however good the instrument. Our engineers site it, wire it and prove it.

Recalibration of existing units

Where the monitor is sound but drifting, recalibration is included in a service visit and costs a fraction of replacement.

On-site calibration

A factory calibration does not know your ductwork

Every monitor arrives calibrated. That calibration was performed on a test rig, against clean reference conditions, with none of the things that actually determine airflow in your building.

Your duct run has bends, length, shared manifolds and a fan that has aged. The room has doors, walkways and general ventilation moving air past the aperture. The cupboard sits where the building put it, not where a laboratory designer would have chosen. None of that was in the factory figure.

Calibrating in situ is the only way the alarm threshold corresponds to the real face velocity. Anything else is an instrument reporting confidently about conditions it has never seen.

REAL CONDITIONS

Set against measured face velocity at the working aperture, with the room’s own air movement in play.

CERTIFIED

Detailed calibration certificate issued for your records, referenced to the unit’s asset number.

ANY MAKE

Extensive experience across the monitor types found in UK laboratories, not only the ones we supply.

NATIONWIDE

Our own qualified engineers travelling to your site, so calibration is not a reason to ship equipment away.

Calibration is carried out as part of annual testing or on its own.

Where we fit them

Monitors specified for the setting

IMAGE — 480×300
University research lab

Universities

Mixed-age estates where a single monitor type across hundreds of units simplifies training and spares.

IMAGE — 480×300
Commercial analytical lab

Laboratories

Contract and analytical labs where a documented calibration trail is part of accreditation.

IMAGE — 480×300
Pharmaceutical production

Pharmaceuticals

Validated environments where alarm thresholds and certificates must match the process documentation.

IMAGE — 480×300
School science laboratory

Schools & Colleges

Clear, unambiguous displays that a technician or teaching staff can read at a glance and act on.

Alarm FAQs

Monitor and alarm questions

More on our full FAQ page.

COSHH requires that control measures are maintained in efficient working order, and BS EN 14175 expects fume cupboards to have a means of indicating that airflow is adequate. In practice, a cupboard in regular use without a working monitor is very difficult to defend.

Not necessarily. It may be a genuine drop in airflow, a sash left too high, or a monitor that has drifted and is alarming at the wrong threshold. All three need measuring to tell apart. Do not silence a persistent alarm and carry on — call us and we will establish which it is.

At every thorough examination, so at least annually. We recalibrate as part of the test visit rather than treating it as a separate job, and after any work that changes the airflow — a new fan, altered ductwork, replaced filters.

Almost always. Retrofitting an alarm to a sound older cupboard is one of the most cost-effective safety improvements available, and considerably cheaper than replacing the unit. We will confirm feasibility from the make, model and duct arrangement.

We will supply to a competent in-house team, but we would advise against it on this particular item. Sensor placement determines whether the reading means anything, and a monitor fitted in the wrong position gives false reassurance that is worse than an obvious fault.

Request a quote

Alarms, monitors and calibration

Tell us the make and model if you know it, or photograph the existing monitor and we will identify what fits.