Airflow alarm sounding
Either the airflow really has dropped, or the monitor has drifted and is reporting a fault that is not there. Both need measuring before anything is replaced.
Likely part
UK · European · USA models
A cupboard out of service stops the work in front of it. We attend, diagnose and where possible repair on the first visit, with common spares carried on the van.
Unit failed and the lab is down? Call the office and describe the fault. You will speak to someone who knows fume cupboards, not a call handler reading a script.
Common faults
Most breakdowns come down to one of five things. If you recognise the symptom, the part it needs is linked below.
Either the airflow really has dropped, or the monitor has drifted and is reporting a fault that is not there. Both need measuring before anything is replaced.
Likely part
Slack or broken belts, worn bearings, a seized motor or a tripped starter. Noise almost always precedes failure, so a rumble is worth reporting early.
Likely part
On a ductless unit this usually means filter breakthrough, and the cupboard should be taken out of use until it is confirmed. On a ducted unit it points to a leak or reverse flow.
Likely part
Counterbalance cables fray and pulleys seize. A sash that drops is a hazard in its own right, quite apart from the containment it stops working.
Likely part
A fail on face velocity or containment needs the cause found, not the symptom patched. We work from your report, whoever carried out the test.
Related
Lighting, service taps, drainage, controls, glazing, liner damage. If it is part of the cupboard, we repair it.
What we repair
Our engineers are trained across UK, European and USA manufactured equipment and are DBS checked, which matters when the work is in a school or a hospital.
We hold a large range of spare parts and consumables for our own equipment and can quickly source parts required for other makes and models.
One contractor, four jobs
A breakdown usually raises a question about the test, the service interval or whether the unit is worth keeping at all. We cover all of it, so you are not coordinating three contractors around one cupboard.
If the fault could affect containment — an airflow alarm, a smell in the room, a sash that will not hold — take it out of use and label it. Call us and we will advise on the specific symptom before you lose a day’s work unnecessarily.
Yes. There is no requirement to be an existing service client. Tell us the make and model if you have it, and photograph the data plate and the fault if you can — it often means the right part is on the van.
Usually, yes. A well-built cupboard has a long life and most failures are in replaceable components rather than the structure. Where it genuinely is beyond economic repair we will say so, and can quote a refurbished replacement and removal of the old unit.
If the repair touched anything affecting airflow — fan, motor, ductwork, filters, sash geometry — the unit should be retested before it returns to service. We can do that on the same visit.
Yes, all of them. A great deal of our work is in schools, colleges and hospitals, so it is a condition of the job rather than an optional extra.
Report a fault
If the unit is out of service and the work is held up, phone rather than email — 0113 245 4111.