Holliday Technical Services

BS EN 14175 · COSHH Reg 9 · HSG258

Independent Fume Cupboard Testing, Servicing & Compliance Across the UK

Certified testing and preventive maintenance for all ducted and ductless recirculating units. Fully compliant with BS EN 14175 and COSHH regulations.

Emergency breakdown support — 0113 245 4111

15,000+

Units tested and serviced

100%

COSHH & BS EN 14175 compliant reporting

All makes

UK, US and European models serviced

Nationwide

Mobile engineers covering the whole UK

Core services

One partner for testing, repair and planned maintenance

From routine fume cupboard testing and maintenance to complex repairs and brand-new installations, HTS is your one-stop shop for fume cupboard servicing.

Fume Cupboard Testing

Face velocity readings, containment checks and smoke visualisation, documented against BS EN 14175 with a full compliance certificate.

Repair & Filter Replacement

Sash mechanisms, airflow monitors, fans and controls, plus HEPA and carbon filter changes on ductless recirculating units.

Planned Preventative Maintenance

Fixed-schedule PPM contracts with calibration, remedial quoting and reminders, so annual testing never slips past its due date.

LEV & Extract System Testing

Thorough examination and testing of local exhaust ventilation to HSG258, covering ductwork, capture hoods and discharge points.

Audit-ready laboratories

Why schools, universities and commercial labs choose HTS

Whether you manage a major laboratory or a single school workshop, we test to the same standard. Every visit produces a written report you can put straight in front of an inspector, listing each unit, its readings, its pass or fail status and any remedial work required.

Fume cupboard servicing is our core business, not a sideline. It accounts for over 80% of our work, and that concentration is why our engineers arrive knowing your make and model already. We work around teaching timetables, shutdown weeks and clinical schedules to keep disruption to a minimum.

We are independent, so the advice you get is about keeping your people safe and your records straight, not about selling you a new cupboard.

Standards we test to

The regulations behind every certificate we issue

BS EN 14175

On-site performance testing

Face velocity, air flow visualisation and containment, tested in situ as Part 4 requires.

COSHH Reg 9

Thorough examination and test

Statutory examination at intervals no longer than 14 months, with records kept for five years.

HSG258

Controlling airborne contaminants

HSE guidance for LEV design, commissioning and thorough examination of extract systems.

CLEAPSS

School and college guidance

Testing and record-keeping aligned to CLEAPSS advice for education science facilities.

Common questions

Testing intervals, filters and response times

If your question is not here, call the office and speak to an engineer rather than a call handler.

COSHH Regulation 9 requires a thorough examination and test at intervals of no more than 14 months. Most laboratories work to a 12-month cycle so the certificate never lapses, and because an annual date is easier to plan around than a rolling 14-month one.

Yes. Ducted units are assessed on face velocity, containment and extract performance. Ductless recirculating units add filter condition and breakthrough to that list, since the air returns to the room. We record filter type, install date and remaining service life at every visit.

It depends entirely on what you use the cupboard for and how heavily. Light teaching use may give several years; sustained solvent work can exhaust a carbon filter far sooner. We advise on a replacement interval based on your usage rather than a generic figure.

Call 0113 245 4111 and we will talk through the fault immediately. Where a unit has to be taken out of service, we prioritise the visit and carry common spares so that many faults are cleared on the first attendance.

We work on any make or model of fume cupboard, including UK, US and European manufacturers, and we supply the matching spares, filters and airflow monitors.

Client feedback

Trusted in education, healthcare and industry

We have worked with HTS on many projects over the years. Always provide a first class service.

Will Perrott St Michael’s Secondary School

Always great communication and thorough servicing and we will continue to use their services as we always have done – thank you.

Sarah Plews Queen Ethelburga’s Collegiate

Excellent service provided by the whole team which is much appreciated.

Joanne Harper Leeds City College

Case studies & guidance

Recent articles

IMAGE — 640×360
Clean fume cupboard interior

Maintenance

Cleaning a Fume Cupboard: Best Practices and Tips

What lab teams can safely do themselves between service visits, and what should be left to an engineer.

IMAGE — 640×360
Anemometer / test instrument in use

Compliance

DOP Testing Explained

What a DOP test proves about filter integrity, when it is required and how the result is recorded.

IMAGE — 640×360
Lab technician at a fume cupboard

Safety

Fume Cupboards: Your Lab's Safety Backbone

How containment failures develop quietly, and the checks that catch them before an audit does.

Accredited and independently assessed

  • Constructionline LOGO — SVG needed
  • BSI LOGO — SVG needed
  • Reset Compliance LOGO — SVG needed
  • SafeContractor LOGO — SVG needed

Request a quote

Request a testing & compliance quote

Tell us how many units you have and what type they are. We will come back with a price and an available date.

Consent
Scroll to Top